Use published BTU/h as the primary cooling-capacity number and keep rating conditions attached to it.
1. What HP tells you
Horsepower is a machinery class, not a universal refrigeration-capacity conversion. Compressor, refrigerant, heat exchanger and rating method differ by product.
2. What BTU/h tells you
BTU/h maps directly to heat-removal rate. That makes it more useful for a water-cooling problem, but it still must be interpreted under its rating conditions.
3. Real examples
| Model | Nominal HP | Published BTU/h |
|---|---|---|
| Active Aqua AACH50HP | 1/2 HP | 4,020 |
| Penguin Standard | 1/2 HP | 5,000 |
| Penguin High Efficiency | 1/2 HP | 5,750 |
Those are meaningfully different outputs behind the same nominal HP label.
4. Rating conditions matter
Active Aqua publishes both BTU test conditions and separate performance-chart conditions. Its manual explicitly says refrigeration efficiency depends on ambient, installation, heat sources, pump and connecting parts. That is why a sourced BTU plus a rating note is better data than HP alone.
5. How to compare chillers
- BTU/h and test/rating note.
- Minimum/maximum flow.
- Operating water range.
- Indoor/outdoor rating.
- Electrical input.
- Connections and service support.
- Independent evidence from similar setups.